Schema for HPC system description
System name.
Must be at least 1 characters long
Hosting facility / provider information.
Provider / hosting facility name.
Must be at least 1 characters long
Physical location of the provider.
Persistent identifier for the provider (e.g. ROR ID).
Type / name of the identifier (ROR, etc.)
Value of identifier (the actual ID)
Provider website URL.
Free-form key-value metadata.
Each additional property must conform to the following schema
Type: objectFree-text comment.
Physical location.
Must be at least 1 characters long
Installation date (RFC3339: YYYY-MM-DDTHH:MM:SSZ).
System partitions or components.
Must contain a minimum of 1 items
Unique identifier for this part (UUID or semantic ID).
Must be at least 1 characters long
Human-readable partition name.
Must be at least 1 characters long
Part provider.
Product name (optional).
Date installation started (RFC3339).
Date accepted (RFC3339, optional).
List of funding entities.
No Additional ItemsMust be at least 1 characters long
Part type: compute, other, or storage.
Required if part_type is 'other'.
Number of nodes in this part.
Value must be greater or equal to 1
Peak power draw.
Numeric value.
Unit of measurement.
Must be at least 1 characters long
Optional comment or notes about this value.
Average power draw.
Numeric value.
Unit of measurement.
Must be at least 1 characters long
Optional comment or notes about this value.
Shared/network storage system data (separate from on-node storage (for this, see below)). Add cumulative storage data here, if part is storage.
Unique identifier for this storage type.
Must be at least 1 characters long
Storage name.
Must be at least 1 characters long
Storage type.
Must be at least 1 characters long
Manufacturer.
Product name.
Storage per node with unit.
Numeric value.
Unit of measurement.
Must be at least 1 characters long
Optional comment or notes about this value.
Total storage with unit.
Numeric value.
Unit of measurement.
Must be at least 1 characters long
Optional comment or notes about this value.
Storage bandwidth with unit.
Numeric value.
Unit of measurement.
Must be at least 1 characters long
Optional comment or notes about this value.
Storage blocksize with unit.
Numeric value.
Unit of measurement.
Must be at least 1 characters long
Optional comment or notes about this value.
I/O operations per second.
Link between CPU and storage.
Unique identifier for this link type.
Must be at least 1 characters long
Link type.
Must be at least 1 characters long
Link bandwidth with unit.
Numeric value.
Unit of measurement.
Must be at least 1 characters long
Optional comment or notes about this value.
Optional comment or notes about this link.
Optional comment or notes about this storage configuration.
File systems this storage system provides.
No Additional ItemsA file system as offered to the users of a system.
Paths at which this file system is mounted.
Must contain a minimum of 1 items
Role of the file system.
Usable capacity.
Numeric value.
Unit of measurement.
Must be at least 1 characters long
Optional comment or notes about this value.
Block size.
Numeric value.
Unit of measurement.
Must be at least 1 characters long
Optional comment or notes about this value.
Backup regime.
From where the file system is mounted.
Deletion or migration policy.
Free-form metadata (site-specific names, environment variables, ...).
Same definition as further_metadataStorage role.
Partitions or queues the scheduler exposes for this part.
No Additional ItemsA partition or queue that the scheduler exposes for a part.
Partition or queue name as the scheduler knows it.
Maximum walltime a job may request in this partition, as HH:MM:SS.
Maximum number of nodes a single job may request in this partition.
Value must be greater or equal to 1
Power consumption details (optional).
Thermal Design Power per node in kW.
Maximum power consumption in kW.
Free-text comment.
Optional comment or notes about this system part.
Name of the parent part to inherit from. All fields are inherited unless explicitly overridden in this part definition.
Node type designs for this part (1..N node types). Each entry represents a distinct node configuration.
Must contain a minimum of 1 items
Node type design specification. A part can have multiple node types (1..N).
Unique identifier for this node type.
Must be at least 1 characters long
Human-readable name for this node type within the part.
Must be at least 1 characters long
Number of nodes of this type.
Value must be greater or equal to 1
CPU specifications for this node type (1..N CPU types).
Must contain a minimum of 1 items
Details about CPU, data per CPU, not accumulated.
Unique identifier for this CPU type.
Must be at least 1 characters long
CPU manufacturer (free text, 'AMD', 'Intel', 'Ampere Computing').
CPU model name.
Must be at least 1 characters long
CPU SKU or part number.
CPU microarchitecture.
Instruction Set Architecture.
Number of cores per CPU.
Value must be greater or equal to 1
Hardware threads per core.
Value must be greater or equal to 1
Thermal Design Power (TDP) with unit.
Numeric value.
Unit of measurement.
Must be at least 1 characters long
Optional comment or notes about this value.
Available power modes.
No Additional ItemsLink between CPUs.
Unique identifier for this link type.
Must be at least 1 characters long
Link type.
Must be at least 1 characters long
Link bandwidth with unit.
Numeric value.
Unit of measurement.
Must be at least 1 characters long
Optional comment or notes about this value.
Optional comment or notes about this link.
Cache levels (hwloc-style).
No Additional ItemsUnique identifier for this cache level.
Must be at least 1 characters long
Cache level name.
Must be at least 1 characters long
Cache type.
Cache size with unit.
Numeric value.
Unit of measurement.
Must be at least 1 characters long
Optional comment or notes about this value.
Cache associativity.
Cache line size with unit.
Numeric value.
Unit of measurement.
Must be at least 1 characters long
Optional comment or notes about this value.
Number of cache instances per CPU.
Value must be greater or equal to 1
Optional comment or notes about this cache level.
Optional comment or notes about this CPU configuration.
Base clock rate.
Numeric value.
Unit of measurement.
Must be at least 1 characters long
Optional comment or notes about this value.
Max boost clock rate.
Numeric value.
Unit of measurement.
Must be at least 1 characters long
Optional comment or notes about this value.
Number of this CPU type per socket (for multi-socket systems).
Value must be greater or equal to 1
Memory specifications for this node type (1..N memory types).
Must contain a minimum of 1 items
Unique identifier for this memory type.
Must be at least 1 characters long
Memory type.
Must be at least 1 characters long
Memory bandwidth with unit.
Numeric value.
Unit of measurement.
Must be at least 1 characters long
Optional comment or notes about this value.
Number of DIMMs, Stacks, etc.
Number of memory channels.
Number of NUMA domains.
Value must be greater or equal to 1
Optional comment or notes about this memory configuration.
Accelerator specifications for this node type (0..N types).
No Additional ItemsDetails of accelerator. Data per accelerator, not accumulated.
Unique identifier for this accelerator type.
Must be at least 1 characters long
Accelerator kind.
Accelerator manufacturer.
Model name.
Must be at least 1 characters long
SKU or part number.
Accelerator microarchitecture.
Instruction Set Architecture or programming model.
Number of accelerators per node.
Value must be greater or equal to 1
Accelerator memory specification.
Same definition as parts_items_node_types_items_memory_itemsThermal Design Power (TDP) with unit.
Numeric value.
Unit of measurement.
Must be at least 1 characters long
Optional comment or notes about this value.
Available power modes.
No Additional ItemsLink between CPU and accelerator.
Unique identifier for this link type.
Must be at least 1 characters long
Link type.
Must be at least 1 characters long
Link bandwidth with unit.
Numeric value.
Unit of measurement.
Must be at least 1 characters long
Optional comment or notes about this value.
Optional comment or notes about this link.
Link between accelerators.
Unique identifier for this link type.
Must be at least 1 characters long
Link type.
Must be at least 1 characters long
Link bandwidth with unit.
Numeric value.
Unit of measurement.
Must be at least 1 characters long
Optional comment or notes about this value.
Optional comment or notes about this link.
Cache levels (hwloc-style, L1, L2, Shared for GPUs).
No Additional ItemsOptional comment or notes about this accelerator.
Number of accelerator cores.
Clock rate.
Numeric value.
Unit of measurement.
Must be at least 1 characters long
Optional comment or notes about this value.
On-node storage specifications for this node type (0..N types).
No Additional ItemsNUMA topology for this node type.
No Additional ItemsUnique identifier for this NUMA domain.
Must be at least 1 characters long
NUMA domain ID.
Value must be greater or equal to 0
Memory size with unit.
Numeric value.
Unit of measurement.
Must be at least 1 characters long
Optional comment or notes about this value.
List of CPU IDs belonging to this NUMA domain.
No Additional ItemsDistances to other NUMA domains (keyed by domain ID).
Each additional property must conform to the following schema
Type: stringList of accelerator IDs associated with this NUMA domain.
No Additional ItemsOptional comment or notes about this NUMA domain.
Optional comment for this node type.
Network connections for this node type (0..N types; node-specific view of the network). Only use relevant keys from description.
No Additional ItemsDetails of adapter. Data per adapter, not accumulated.
Unique identifier for this network adapter type.
Must be at least 1 characters long
Interconnect type.
Must be at least 1 characters long
Manufacturer.
SKU or model.
Number of interconnect adapters per node.
Value must be greater or equal to 1
Link between adapter and switch(/other adapter), including bandwidth.
Same definition as cpu_to_storage_linkLink between CPU and network adapter, including bandwidth.
Same definition as cpu_to_storage_linkFree-text comment.
Node type name to inherit from within the same part. All fields are inherited unless explicitly overridden in this node type definition.
Network/interconnect specifications for this part (0..N types). This is the part-level view of the network.
No Additional ItemsUnique identifier for this network.
Must be at least 1 characters long
Name of this network component
Must be at least 1 characters long
Interconnect type.
Must be at least 1 characters long
Manufacturer.
SKU or model number.
Number of interconnect adapters per node.
Value must be greater or equal to 1
Network topology.
Detailed information about each topology component, one or more.
No Additional ItemsUnique identifier for this topology component.
Must be at least 1 characters long
Name of this network component
Must be at least 1 characters long
Bandwidth of links within this component.
Unique identifier for this link type.
Must be at least 1 characters long
Link type.
Must be at least 1 characters long
Link bandwidth with unit.
Numeric value.
Unit of measurement.
Must be at least 1 characters long
Optional comment or notes about this value.
Optional comment or notes about this link.
Rail Type.
Total number of available links.
Bisection bandwidth of this component with unit.
Numeric value.
Unit of measurement.
Must be at least 1 characters long
Optional comment or notes about this value.
Total number of switches in this component.
Available features.
No Additional ItemsFree-text comment.
Bisection bandwidth of this component with unit.
Numeric value.
Unit of measurement.
Must be at least 1 characters long
Optional comment or notes about this value.
Optional comment or notes about this interconnect.
Cooling infrastructure for this part (optional).
Cooling type.
Must be at least 1 characters long
Cooling capacity with unit.
Numeric value.
Unit of measurement.
Must be at least 1 characters long
Optional comment or notes about this value.
Cooling efficiency (e.g., PUE, COP).
Value must be greater or equal to 0
Optional comment or notes about cooling.
Physical location of this part (optional).
Site or campus name.
Must be at least 1 characters long
Datacenter name or code.
Must be at least 1 characters long
Hall or building section.
Rack row identifier.
Rack identifier.
Unit or U position in rack.
Optional comment or notes about location.
Software stack for this part.
System-level software (OS, kernel, firmware).
Operating system information.
OS type.
Must be at least 1 characters long
OS distribution/flavor.
OS version.
Must be at least 1 characters long
Optional comment or notes about this OS.
Kernel version.
Firmware versions for various components.
No Additional ItemsComponent name.
Must be at least 1 characters long
Firmware version string.
Must be at least 1 characters long
Optional comment or notes about this firmware.
Optional comment or notes about system software.
Job scheduler (optional).
Scheduler name.
Scheduler version.
User-level software (compilers, MPIs, libraries).
Available compilers.
No Additional ItemsPackage name.
Must be at least 1 characters long
Version string.
Must be at least 1 characters long
Variant or build options.
Optional comment or notes about this software package.
C library version.
MPI implementations.
No Additional ItemsBLAS libraries.
No Additional ItemsKey libraries.
No Additional ItemsOther software components.
Each additional property must conform to the following schema
Type: stringOptional comment or notes about user software.
Optional comment or notes about the software stack.
System website URL (optional).
Free-form key-value metadata.
Each additional property must conform to the following schema
Type: objectOptional comment or notes about this system definition.
Semantic version of this document (user-provided)
Must match regular expression:^[0-9]+\.[0-9]+\.[0-9]+$
Schema version this document conforms to (maintainer-defined)